IN THE LAB |
COLOR TEMPERATURE (Warm setting, before/after calibration) Low window........................................................ NA/6,532 K High window.................................................... 6,354/6,504 K BRIGHTNESS (Warm setting, before/after calibration)......... 34.8/29.2 ftL Precalibration measurements were made after initial adjustments with the Avia test DVD. The set provides three color-temperature options: Cool, Neutral, and Warm. Prior to calibration, the Warm preset measured close to the NTSC 6,500-K standard on the high (100-IRE) window but displayed a strong bias toward green on the low (20-IRE) window. For this reason, I recommend hiring a professional to calibrate the set's grayscale. The Imaging Science Foundation (561-997-9073) can help you locate a certified technician. After calibration, grayscale tracking was only fair, ranging ±500 K at each 10-IRE step between 20 and 100 IRE. The performance of the set's 3-D digital comb filter was excellent, delivering clean transitions in an SMPTE color-bars pattern when the composite-video inputs were used. NTSC decoding was accurate. Geometry was excellent in both the set's widescreen and 4:3 display modes. - A.G. |
(Originally published in: Sound & Vision, May 2001)